What is the PCM100?

The PCM100 is an integrated portable surface contamination monitor designed to measure alpha, beta and gamma contamination. The manufacturer states that it uses three end-window GM tubes with a combined 45 cm² sensitive area and supports count, CPS, Bq and Bq/cm² display modes.

The PCM100 may support contamination surveys in nuclear facilities, decommissioning projects, radioactivity laboratories and other controlled areas. Buyers should define target radionuclides, scan geometry, required efficiency, background conditions, units, calibration sources and data-record requirements.

NRD listing status: This page is a sourcing and quotation reference. Supply, exact revision, supporting documents, lead time and commercial terms are confirmed for each enquiry.

B2B quotation and model check

Tell us the application, quantity and destination.

We will confirm the current revision, configuration, available documents, MOQ, lead time and commercial terms.

B2B priceRequest a quotation
AvailabilityConfirmed per enquiry
Source modelPCM100

What are the key PCM100 specifications?

The following values are attributed to the manufacturer source. They support initial comparison, but buyers should confirm the current data sheet, test conditions and exact quoted configuration before ordering.

Parameter Manufacturer-stated value Buyer check
Detector Three end-window GM counter tubes Confirm with the current quotation and data sheet
Radiation types Alpha, beta and gamma Confirm with the current quotation and data sheet
Sensitive area 45 cm² total Confirm with the current quotation and data sheet
Display units Total count, CPS, Bq and Bq/cm² Confirm with the current quotation and data sheet
Count-rate range 0.1 to 100,000 CPS Confirm with the current quotation and data sheet
Surface activity range 0.1 to 1,000 Bq/cm² Confirm with the current quotation and data sheet
Energy lower limit Alpha 2.5 MeV, beta 30 keV, gamma 5 keV Confirm with the current quotation and data sheet
Power 4.2 V rechargeable battery, more than 100 hours stated operation Confirm with the current quotation and data sheet
Dimensions 226 x 140 x 88 mm Confirm with the current quotation and data sheet
Weight Approximately 1.5 kg Confirm with the current quotation and data sheet
Technical source: PCM100 official product information. Source reviewed on 2 October 2026.
B2B quotation and model check

Tell us the application, quantity and destination.

We will confirm the current revision, configuration, available documents, MOQ, lead time and commercial terms.

Where can the PCM100 be used?

Work-surface contamination checks

Describe the radiation type, expected range, operating workflow and required evidence when requesting this configuration.

Nuclear facility decommissioning

Describe the radiation type, expected range, operating workflow and required evidence when requesting this configuration.

Laboratory contamination surveys

Describe the radiation type, expected range, operating workflow and required evidence when requesting this configuration.

Equipment and controlled-area inspection

Describe the radiation type, expected range, operating workflow and required evidence when requesting this configuration.

What should buyers verify before ordering the PCM100?

Exact detector and revision

Confirm detector technology, production revision, firmware, interface language, accessories and package contents.

Measurement task

State radiation type, expected range, units, background conditions, alarms and operating environment.

Calibration and documents

Name the required data sheet, calibration field, standard, issuing body, traceability and report language.

Commercial terms

Confirm quantity, MOQ, sample route, lead time, packaging, Incoterms, warranty and support before payment.

PCM100 buyer questions

Is the PCM100 available from stock?

Stock is not claimed on this website. Current revision, quantity and lead time are confirmed during quotation.

Is calibration documentation included?

Calibration scope is confirmed for the exact quoted unit. State the required standard, laboratory and destination-market needs.

Can it be supplied for OEM orders?

Labels, language, packaging and accessories can be reviewed for qualified quantities. Feasibility and MOQ depend on the supplier route.

Why is there no fixed online price?

Configuration, quantity, documentation, destination, shipping and customization can change B2B commercial terms.

Key terms for evaluating the PCM100

Detector type

The sensing technology determines which radiation can be measured and how the instrument responds.

Measurement range

The range states the minimum and maximum values under specified conditions.

Energy response

Energy response describes how detector sensitivity changes across radiation energies.

Alarm threshold

An alarm threshold is a user-set level that triggers an audible, visual or vibration alert.

Calibration evidence

Calibration evidence documents how a specific instrument was checked against stated references.